Oplossingen
KostenreductieESG & ComplianceHuurdersfacturatie & betrokkenheidVastgoedbeheerPortefeuillebeheerUtility Data API
Product
PlatformElektriciteitsmonitoringWatermonitoringGasmonitoringWarmtemonitoringZonnestroommonitoringDatabronnenHardwareUtiliteitsconnectorenInfrastructuur van derden
Tools
Alle toolsMetercompatibiliteitDekking energieleveranciers
Industrieën
Alle industrieënLogistiekRetailKantoorResidentieelStudentenhuisvestingHospitalityZorgvastgoed
Case studiesBlogPartners
ENPLDE
Demo aanvragen

Which meters can Rhino read over Wireless M-Bus OMS?

Any of them. Wireless M-Bus OMS is an open protocol and the Rhino access point speaks it natively, so a meter using it can be read whether or not we have set that model up before. What you need on site is a Rhino WMBus RS232.

Wireless M-Bus in the OMS profile is the 868 MHz radio version of M-Bus, and it is what most modern heat, water and gas submeters ship with. The meter broadcasts its reading on a schedule rather than waiting to be asked.

Rhino receives those broadcasts with a WMBus RS232 device. Nothing is wired to the meter, which makes this the least invasive route into a building and the usual answer in apartment blocks and multi-tenant floors.

Range is the design constraint. Expect around 300 m line of sight and considerably less through floors and cores, so a Rhino WMBus Repeater is normal on anything taller or deeper than a single plate.

Rhino device
Rhino WMBus RS232
Also needed
One Rhino AP per building
Utilities
Electricity, Heat, Water, Gas, Sensor
Listed model required
No

Any meter that speaks Modbus or M-Bus connects to the Rhino AP, whether or not we have set that model up before. What we have already configured is a record of past work, not a boundary. Tell us what you have at sales@rhino.energy and we will name the device you need.

Already configured

Every Wireless M-Bus OMS meter connects.

Below are the ones Rhino has already set up, reviewed 2026-08-25. Anything else on Wireless M-Bus OMS connects the same way and has simply not been configured yet.

ManufacturerModelUtilityAll protocols on this meterMID
ABBB23ElectricityPulse / S0 and Wireless M-Bus OMSYes
ApatorELF2HeatWireless M-Bus OMS
ApatorFaun-D204MBHeatRS485 Modbus and Wireless M-Bus OMS
ApatorJS Master+WaterM-Bus wired, Wireless M-Bus OMS and Pulse / S0
ApatorJS Smart+WaterM-Bus wired, Wireless M-Bus OMS and Pulse / S0
ApatorMWNWaterWireless M-Bus OMS and Pulse / S0
ApatorUGGasWireless M-Bus OMS and Pulse / S0
ApatorUltrimis WWaterWireless M-Bus OMS
AxiomaQalcosonic W1WaterWireless M-Bus OMS
AxiomaQualcosonicE3HeatWireless M-Bus OMS
BMetersGMB-IWaterM-Bus wired, Pulse / S0 and Wireless M-Bus OMS
BMetersGMDM-IWaterM-Bus wired, Pulse / S0 and Wireless M-Bus OMS
BMetersGSD8-RFMWaterM-Bus wired and Wireless M-Bus OMS
BMetersHydrocal M4HeatWireless M-Bus OMS
BMetersHydrosonis ULC T330HeatWireless M-Bus OMS
BMetersWDE-K50WaterPulse / S0 and Wireless M-Bus OMS
DiehlAltairWaterWireless M-Bus OMS
DiehlSharky 775HeatWireless M-Bus OMS
ElvacoCMa20WSensorWireless M-Bus OMS
ElvacoSense 300WSensorWireless M-Bus OMS
ItronACD GGasPulse / S0 and Wireless M-Bus OMS
ItronAquadis+WaterPulse / S0 and Wireless M-Bus OMS
ItronDelta QDGasPulse / S0 and Wireless M-Bus OMS
ItronDelta rotary meterGasPulse / S0 and Wireless M-Bus OMS
ItronFlodisWaterPulse / S0 and Wireless M-Bus OMS
ItronFlostar MWaterPulse / S0 and Wireless M-Bus OMS
ItronFlostar SWaterPulse / S0 and Wireless M-Bus OMS
ItronFluxi 2000/TZGasPulse / S0 and Wireless M-Bus OMS
ItronGallusGasPulse / S0 and Wireless M-Bus OMS
ItronMZGasPulse / S0 and Wireless M-Bus OMS
ItronRF1GasPulse / S0 and Wireless M-Bus OMS
ItronUnimag+WaterPulse / S0 and Wireless M-Bus OMS
ItronWoltex MWaterPulse / S0 and Wireless M-Bus OMS
KamstrupFlowIQ2200WaterWireless M-Bus OMS
KamstrupFlowIQ3100WaterWireless M-Bus OMS
KamstrupMultical 402HeatM-Bus wired and Wireless M-Bus OMS
KamstrupMultical 403HeatM-Bus wired and Wireless M-Bus OMS
KamstrupMultical 603HeatM-Bus wired and Wireless M-Bus OMS
KamstrupMultical 21WaterWireless M-Bus OMS
KamstrupOmnipowerElectricityM-Bus wired and Wireless M-Bus OMSYes
Landis GyrUH50 (T550)HeatM-Bus wired, RS485 Modbus and Wireless M-Bus OMS
LansenLAN-WMBUS-E2-CO2SensorWireless M-Bus OMS
QundisQwater5.5WaterWireless M-Bus OMS
Sensus640WaterWireless M-Bus OMS
SensusIperlWaterWireless M-Bus OMS
SiemensWSM515HeatWireless M-Bus OMS
SontexSupercal739HeatWireless M-Bus OMS

Know the protocol. Now do the building.